Technical Library

SANS Compliance Hub

South Africa's glazing rules, stated plainly and referenced to the standard they come from. Written for architects, quantity surveyors, engineers and contractors who have to defend a specification, and for homeowners who do not want to pay twice for a door that was glazed with the wrong glass.

Standards and industry bodies interpreted in this library
SANS 10400-NSANS 1263-1SANS 10400-XASANS 204SANS 10400-TSANS 1253SANS 10160AAAMSASAGGA
Quick reference

The rule that fails most projects first

Glazing is the discipline where non-compliance is invisible until it is inspected, or until it is broken. Start with where safety glass is compulsory.

Where safety glass is compulsory

SANS 10400-N, with impact performance per SANS 1263-1. Class A is a 400 J drop-bag rating.

LocationWhat triggers itMinimum requirement
Doors and side panelsAny glazing within 300 mm of a door frame openingClass A safety glass
Low-level glazingAny pane installed lower than 800 mm from the finished floor levelClass A safety glass
Bathrooms and wet areasAll shower cubicles, bath screens and panels within 2.1 m of the floorToughened safety glass, minimum 6–8 mm, or 10 mm for frameless; laminated safety glass also accepted
Overhead and roof glazingSkylights, rooflights, canopies and any glazing above head heightLaminated safety glass, so shards are retained on failure rather than falling
Frameless doors and balustradesStructural glass with no frame to hold the panel in placeToughened or toughened laminated: 10–12 mm for post systems; 12–15 mm and heavier for base-channel cantilevered systems, per SANS 10160 line loads
Public and hazard areasMirrors in gyms, dance studios, schools, malls and change roomsFoil-backed safety mirror or mechanically secured safety glass

Turn this table into a specification

Describe the opening — its type, height above the floor, distance from a door, province and exposure — and the specifier returns the required glass class, minimum thickness, dead weight, deflection limit and thermal target, each with the rule it came from.

Open the Glazing Specifier
Technical library

Guides by standard

Each guide states the requirement, the standard it comes from, and what it means on a South African site.

SANS 10400-N · SANS 1263-1

Safety Glazing

Where safety glass is compulsory, which class it must be, and why annealed float in a door is an open liability.

SANS 10400-T · SANS 1253

Fire Safety

Integrity versus insulation rated glazing, escape routes, party walls and fire doors — specified as a tested assembly.

SANS 10160 · AAAMSA · SAGGA

Loads, Fixing & Sign-Off

Balustrade line loads, dead weight and hardware selection, wind and water testing, and the paperwork that closes a project out.

SANS 10400-XA · SANS 204

Energy efficiency by climatic zone

The prescriptive route limits fenestration to a percentage of the net floor area, typically 15%. Past that limit the design must be justified by a rational calculation. Either way, U-value answers how fast heat crosses the assembly and SHGC answers how much solar radiation it admits, and the correct balance is different in every zone.

Climatic zones

What each South African zone asks of the glazing specification.

Climatic zoneWhere it appliesWhat it demands of the glazing
Zone 1 — Cold interiorHighveld: Johannesburg, Pretoria, the Free State and the eastern interiorFavour solar gain in winter but control summer overheating: Low-E glass or a DGU, with SHGC tuned to let winter sun in
Zone 2 — Temperate coastalKwaZulu-Natal coast: Durban, Umhlanga, Richards BayHigh humidity and salt exposure: corrosion-resistant framing, controlled solar gain, and laminated panes chosen for storm and impact performance
Zone 4 — MediterraneanWestern Cape: Cape Town, the Winelands and the Garden RouteStrong winter wind and driving rain: the wind-load and water-penetration class of the system matters as much as the glass, with SHGC kept low against summer sun

The thermal specification ladder

Achievable whole-assembly U-values, with the practical entry point for compliance.

AssemblyU-valueWhen to specify it
4 mm clear float in standard aluminium≈ 5.8 W/m²·KInternal partitions only. Poor for an external envelope.
Toughened single glazing in thermally broken aluminium≈ 4.5–5.0 W/m²·KRenovations where the frame is the dominant heat path and the budget is tight.
Single Low-E glazing≈ 3.5–4.0 W/m²·KExisting single-glazed openings that cannot take a double-glazed rebate.
Double glazed unit, clear≈ 2.7–2.9 W/m²·KThe practical entry point to a compliant envelope.
Double glazed unit with Low-E and argon< 2.8 W/m²·K, down to ≈ 1.6 W/m²·KNew residential and commercial envelopes chasing XA compliance without a rational design.
Work through it before you call the inspector

Fenestration compliance checklist

The items that decide whether a glazing installation passes sign-off the first time. Work through it on site, print it for the file, or send it to us with your schedule.

Self-check

Fenestration compliance check

0 of 23 confirmed before the competent person inspects.

Design and drawings

Safety glazing

Energy and thermal

Fire

Structure, fixing and installation

Documentation and close-out

Reference

Standards and bodies referenced

The documents this library interprets, and what each one governs.

SANS 10400-N

Glazing

Deemed-to-satisfy glazing rules under the National Building Regulations: where safety glass is compulsory, minimum thicknesses and human impact protection.

SANS 1263-1

Impact performance of safety glazing

Architectural safety glazing classification: Class A (400 J drop-bag) and Class B (200 J). Parts 2 and 3 cover ballistic and blast resistance.

SANS 10400-XA

Energy usage in buildings

The prescriptive route for fenestration area, insulation values and solar control in new and extended buildings.

SANS 204

Energy efficiency in buildings

The performance framework behind XA: U-values, SHGC limits and air-tightness by climatic zone.

SANS 10400-T

Fire protection

Fire resistance of elements of construction, including fire-rated glazing in escape routes, party walls and fire doors.

SANS 1253

Fire test methods

The test standard that produces the integrity (E) and insulation (EI) ratings quoted for fire-rated glass assemblies.

SANS 10160

Basis of structural design

Actions on structures, including the horizontal line loads that govern glass balustrades and guard glazing.

AAAMSA

Architectural Aluminium Manufacturers

Wind-load and water-penetration testing, deflection limits and performance classification for aluminium systems.

SAGGA

Glass & Glazing Association of SA

Competent person sign-off, Form 4 submission support and Glazing Certificates of Conformance.

Figures quoted here are the prescriptive requirements of the SANS standards named against each item. Standards are revised periodically and a project's specific conditions (wind category, altitude, exposure, occupancy) can change the answer. Confirm the current edition of the standard and obtain sign-off from the competent person appointed on your project before you fabricate or install.

What we issue

Documentation that closes a project out

Fabricated at our Meadowdale facility in Johannesburg and installed nationwide. Every scope that requires sign-off leaves here with the paperwork that proves what was built.

Glazing Certificate of Conformance

Signed by a SAGGA-registered competent person, naming the glass type, thickness, class and location of every pane we supplied.

AAAMSA performance submission

Wind-load, deflection and water-penetration certification for the aluminium system as installed, with the test classification quoted.

Form 4 submission support

Documentation pack prepared for the local authority on request, so sign-off is not held up by missing glazing evidence.

Fabrication drawings and cut sheets

Dimensioned drawings, glass schedules and profile cut lists issued from our Meadowdale facility against the approved revision.

Thermal and solar schedule

U-value and SHGC values for the specified assemblies, tabled against the climatic zone the project falls in.

Installation and fixing schedule

Anchor type, centres, sealant and drainage details per elevation, so the rated system is not compromised on site.

NovahTech Spring Sale

25% off

Refresh your space with table tops and mirrors.

1–31 October 2026